| Mr. Purvesh shah |
 |
Regd. Office :
Shop No. 3 & 4, Comm. Plot No.
C-3/3, Near State Bank of India, G.I.D.C., Ankleshwar – 393 002,
Dist. Bharuch, Gujarat, India.

Dahej Office :
Sanskar Avenue, Shop No. GF-37,
P.O.Jolva, Tal. Vagra,
Dist. Bharuch, Gujarat, India.

Mob. : 9824345895
Tel Fax (O) : 02646-224805
Email : siddhi_ank@gmail.com
siddhi_ank@rediffmail.com
Website : www.Shubhenviro.com
|
|
|
 |
|
|
Analytical Services |
| |
|
List of parameters analyzed at our laboratory |
|
| Sr. No. |
Test |
Sr. No. |
Test |
| 1 |
TemperatureºC |
21 |
Calcium |
| 2 |
Colour Pt – Co Colour units |
22 |
Magnesium |
| 3 |
Odour |
23 |
Hardness |
| 4 |
Turbidity |
24 |
Sodium |
| 5 |
Total Solids |
25 |
Potassium |
| 6 |
Total Dissolved Solids |
26 |
Iron |
| 7 |
Total Suspended Solids |
27 |
Heavy Metals (Pb, Zn, Cr, Cu, Sb, As, Hg, Cd) |
| 8 |
Dissolved Oxygen |
28 |
Oil & Grease |
| 9 |
Biochemical Oxygen Demand |
29 |
Phenolic Compounds |
| 10 |
Chemical Oxygen Demand |
30 |
Full Boiler Water Analysis |
| 11 |
PH Value |
31 |
Drinking Water Analysis as per IS 15500 : 1991 |
| 12 |
Alkalinity |
32 |
Hazardous Waste Analysis |
| 13 |
Acidity |
33 |
Solid Waste Analysis |
| 14 |
Ammonical Nitrogen |
34 |
Ambient Air Analysis as per revised AAQS standards |
| 15 |
Nitrates |
35 |
Stack Monitoring for PM, SO2 & NOx per stack as well as specific parameters such as HCl, NH3, Chlorine, HC, HBr, Br2, etc. |
| 16 |
Phosphates |
36 |
Coal Analysis % Ash, % Moisture, % V.M., Calorific Value |
| 17 |
Sulphates |
37 |
Hydrated Lime % Ca (OH)2 |
| 18 |
Chlorides |
38 |
Work Place monitoring as per Factories Act and Gujarat Factories Rules |
| 19 |
Residual Chlorine |
39 |
Noise level monitoring using Decibel meter |
| 20 |
Residual Chlorine |
40 |
Site specific Micrometerological parameters recording by Automatic Weather monitoring station |
|
| |
|
 |
Instruments and other facilities at our laboratory : |
|
| |
|
| |
| Sr. No. |
Instrument / Equipment |
Make / Supplier |
Specifications / Capacity / Range of application |
Accuracy of measurement |
Any other detail |
| |
Water sampling and Analysis |
| 1 |
Digital pH Meter |
Elico India |
pH range : 0.00 to 14.00 pH |
±0.01 |
Resolution- ±0.01 |
| 2 |
Weighing Balance |
K- Roy |
Single Pan
Min.weighing –0.001 g
Max. weighing – 200.000 g |
±0.001g |
|
| 3 |
Visible Spectrophotometer (Digital) Model No. CL-310 |
Chemiline |
wavelength range – 340 to 990 nm |
±2 nm
±0.005 Abs |
|
| 4 |
UV-Visible spectrophotometer |
Systronics |
wavelength range – 200 to 1000 nm |
±0.1 nm |
|
| 5 |
Digital Flame
Photometer Model
No. CL-410 |
Chemi Line |
Sodium : 2 To 100 PPM K – 1 to 100 ppm Li – 2 to 25 ppm Ca – 30 to 300 ppm |
±2% & ±1 digit |
|
| 6 |
Oven (Hot Air) |
Labline |
14” x 14” x 14” (250 °C max.) |
±1 deg C |
|
| 7 |
COD Digestor |
Labline |
FOR 15 Samples
at a time |
|
|
| 8 |
Muffle Furnace |
Labline |
1150 °C Max. with silica and porcelein crucibles Size : 10” x 5” x 5” |
±0.3 deg C |
|
| 9 |
Heating Mantle |
Labline |
Cap. : 500 ML |
|
|
| 10 |
B.O.D Incubator |
- |
- |
|
|
| 11 |
Composite testing kit |
Aquasol |
Silica – 5 to 80 ppm Iron – 0 to 10 ppm Sulphate – min. 10 ppm |
|
|
| 12 |
Kjeldhal Assembly |
- |
Cap : 500 ml |
|
|
| 13 |
Distillation unit |
- |
3 litre/hr |
|
|
| 14 |
Digital Direct TDS meter |
Digital Instruments Corporation |
TDS measurement : 0 To 200000 PPM |
±1 % |
|
| 15 |
D.O. Meter |
Chemi Line |
DO measurement : 0 To 20 PPM |
±1 % |
0.1 ppm |
| 16 |
Hot Water Bath |
Jay lab Instruments |
6 Holes |
|
|
| 17 |
Gas Chromatograph |
Netal India Model No. Omega-QCT |
---- |
|
|
| |
Stack Monitoring & Monitoring of gaseous vents |
| 18 |
Stack Monitoring Kit |
Yash Engineers, Baroda |
With stack
velocity measurement,
Dry Gas Meter
and vacuum
pump, Rotameter
- 10 LPM, 100 LPM |
|
Temp – 0 to 500 C |
| 19 |
Handy Sampler (HC sampling) Model No. AS-2 |
Technovation Analytical Inst. (P) Ltd., Mumbai |
Rotameter 0.5 PM |
|
|
| |
Ambient Air Quality Monitoring & Work Place Monitoring |
| 20 |
High Volume Air Sampler (Carbon Brushless) |
Yash Engineers, Baroda |
Model – HNS/HVS/21 |
|
|
| 21 |
Respirable particulate matter sampler |
Yash Engineers, Baroda |
For PM10 measurement |
|
|
| 22 |
Respirable dust
sampler ( for
particulate matter
less than 2.5
micron) |
Yash Engineers, Baroda |
for the
monitoring of
Respirable dust
and gaseous
pollutants like
SO2, NOx etc.
With inbuilt
stabiliser, timer,
time totaliser
including gaseous
assembly for
gaseous measurement, With PM 10 and PM 2.5 impactor anufactured
as per design
standardize by USEPA and
brushless motor. |
|
|
| 23 |
Dragger Tubes and pump |
Uniphos Model No. – ASP-21 |
For Measuring
concentration of diff.solvents and chemical Range – 10 to 2000 ppm |
|
|
| |
Noise Monitoring |
| 24 |
Noise Level Meter |
Lutron Model : SL4010 |
Range : 30 to
130 dB
(3 ranges) |
Resolution – 0.1dB |
|
| |
Site Specific Micrometeorological parameters recording |
| 25 |
Automatic wind monitoring system, model WM 271
with Micro-controller based Data Logger |
Envirotech Instruments Pvt. Ltd., New Delhi
|
Including :
1. Wind Speed Sensor
2. Wind Direction Sensor
3. Temperature and RH Sensor
4. Windows XP compatible Software - MetLog
5. Industry Standard RS232 Data Transfer Cable
6. Tripod Stand, T-Bar and Tools to mount Sensors
7. Magnetic Compass to indicate North & South Poles
8. NiMH Battery for 15 hours power back-up with Charger
9. USB Adapter for data transfer on Laptops
10. Rainfall Sensor
|
|
|
| |
Microbiological Analysis |
| 26 |
Microscope |
C X L Plus |
---- |
|
|
| 27 |
Laminar Air
Flow |
Labline |
2 x 2 x 2 Feet |
|
|
| 28 |
Autoclave |
---- |
---- |
|
|
| 29 |
Digital Colony
Counter |
Chemi line |
CL - 910 , Count 9999 |
0.00% |
Dish size – 110 mm dia |
| 30 |
Magnetic Stirrer
With Hot Plate
|
Jay lab Instruments |
Cap. : 2 litres
|
|
Temp – 100 C
|
|
|
| |