(all major parameters viz. pH, SS, TDS, COD, BOD, DO, chlorides, sulphates, sulphides, phosphate,
O&G, Ammonical Nitrogen, Heavy metals, Bioassay test etc.) |
| |
|
| Stack and Ambient Air monitoring and analysis |
|
 |
(all major parameters viz. SPM, PM, NOx, SOx, HCl, Chlorine, Ammonia, Hydrocarbons etc.) |
| |
|
| Work Area Monitoring (of major chemicals) |
| ENVIRONMENTAL CONSULTANCY |
 |
We are enlisted as ENVIRONMENTAL CONSULTANTS by GUJARAT POLLUTION CONTROL
BOARD (copy of enlistment enclosed) |
| |
|
 |
Treatability study of effluents (for all major types of industries) – for improvement in treatment,
revamping, debottlenecking of treatment plants, cost reduction, implementation of cleaner production
technologies |
| |
|
 |
Our studies focus on minimizing capital costs as well as operating costs for treatment of effluents.
We also make use of newer strategies like Prevention at source and Cleaner production
technology towards reduction in effluent generation and conservation of water resources. |
| |
|
 |
Study for maximum reuse of water in the plant alongwith calculations for savings |
 |
The study includes identifying waste water streams, which can be reused after treatment,
developing schemes for segregation of this streams from main stream, proper collection and
treatment facility, recycling routes etc. The study also provides an estimate of the cost of reusing
water into the plant and the savings gained through reuse of water. |
| |
Our clients have successfully obtained considerable savings through our studies for water reuse. |
| |
|
 |
Design of ETP (new as well as for debottlenecking or expansion)- Complete Design Report with
specifications and flow diagram |
| |
|
 |
ETP operation and troubleshooting or resetup |
| |
|
 |
Consultancy and Liasoning assistance for compliances of Environmental Act viz.
- Consents and Authorization of State Pollution Control board under Water Act, Air Act, and
Hazardous Waste (Management and Handling) Rules,
- No Objection Certificate from State Pollution Control Board
- Environmental Clearance from Ministry of Environment & Forests, New Delhi.
|
| |
|
 |
We provide consultation and assistance to industries for complying with various statutory
requirements of the Environmental Act. It includes obtaining consents and NOC from Gujarat
Pollution Control Board as well as Environmental Clearance from the Ministry of Environment &
Forests (MoEF), New Delhi, starting from preparation of necessary documents and drawings to
follow-up in the proceedings by attending to queries and providing all necessary information and
support to the board or Ministry. |
| |
|
 |
Environmental Impact Assessment(EIA) – Rapid & Comprehensive and Risk Assessment Studies |
 |
We carry out EIA and Risk assessment studies as per the guidelines and formats of MoEF and GPCB
incorporating all necessary environmental aspects and risk scenarios using latest risk assessment softwares. |
| |
|
 |
Infrastructure and support system for Analytical services : |
 |
We have a well-equipped analytical laboratory and all the necessary facilities for general and
specific analysis of raw materials, finished products, air, water effluents and hazardous solid
waste. |
 |
We follow IS and APHA standards for testing procedures, and update our methods of analysis as
per new publications and amendments. At present we are capable of analyzing all major
parameters in accordance with the standard methods of IS and APHA. |
 |
We have all necessary laboratory set-up viz. tiled laboratory work tables, laboratory chemicals,
glassware, equipment and instruments. |
 |
Our instruments are from standard suppliers and regularly calibrated. |
 |
In addition, other facilities include exhaust system for odour prevention, personal protective
equipment (gloves, gas mask, face shield etc.), sufficient area, adequate lighting, laboratory
furniture, separate instrument table, sand buckets, etc. |
 |
We have a team of well-qualified chemists with ample experience and expertise in sampling and
analysis. |
 |
We also provide external training to our chemists from time to time to upgrade their knowledge
w.r.t to new methods of analysis. |
 |
All analytical data are recorded through computerized system. |
| |
|
 |
Infrastructure and support system for Environmental Consultancy : |
 |
Our team comprises of qualified engineers who have gained thorough knowledge in effluent
treatment, design of Effluent treatment plants, ETP operation, etc. This knowledge is coupled with
the expertise of senior professionals to enable to develop methods for pollution control and
prevention for various types of industries. |
 |
We have laboratory scale effluent treatment modules for carrying out treatability of effluents. |
 |
These include flocculation and coagulation tanks for primary treatment, aeration tank for
secondary treatment and mini beds of activated carbon and sand filter for tertiary treatment. The
sizing and hydraulics of ETP are designed based on the results obtained from this lab-scale
treatment. |
 |
In addition to literature related to standards methods of analysis, we have developed a library of
books on environmental chemistry, waste water engineering, pollution control, Hazardous waste
management etc. |
 |
We are life members of UPL Rotary library which is only 1 km from our office, and we utilize this
facility to continuously enrich our knowledge in these fields through regular reading of magazines
and latest books. We have internet connection at our office computers and are members of some
useful sites. |
| |
|
 |
Parameters analysed at our laboratory : |
| |
|
| |
| Sr. No. |
Test |
| 1 |
TemperatureºC |
| 2 |
Colour Pt – Co Colour units |
| 3 |
Odour |
| 4 |
Turbidity |
| 5 |
Total Solids |
| 6 |
Total Dissolved Solids |
| 7 |
Total Suspended Solids |
| 8 |
Dissolved Oxygen |
| 9 |
Biochemical Oxygen Demand |
| 10 |
Chemical Oxygen Demand |
| 11 |
PH Value |
| 12 |
Alkalinity |
| 13 |
Acidity |
| 14 |
Ammonical Nitrogen |
| 15 |
Nitrates |
| 16 |
Phosphates |
| 17 |
Sulphates |
| 18 |
Chlorides |
| 19 |
Residual Chlorine |
| 20 |
Silica |
| 21 |
Calcium |
| 22 |
Magnesium |
| 23 |
Hardness |
| 24 |
Sodium |
| 25 |
Potassium |
| 26 |
Iron |
| 27 |
Heavy Metals (Pb, Zn, Cr, Cu, Sb, As, Hg, Cd) |
| 28 |
Oil & Grease |
| 29 |
Phenolic Compounds |
| 30 |
Full Boiler Water Analysis |
| 31 |
Drinking Water Analysis |
| 32 |
Hazardous Waste Analysis |
| 33 |
Solid Waste Analysis |
| 34 |
Ambient Air Analysis for SPM, SO2 & Nox per station |
| 35 |
Stack Monitoring for PM, SO2 & Nox per stack |
| 36 |
Coal Analysis % Ash, % Moisture, % V.M., Calorific Value |
| 37 |
Hydrated Lime % Ca (OH)2 |
|
| |
|
 |
Instruments and other facilities at our laboratory : |
| |
|
| |
| Sr. No. |
Instrument / Equipment |
Make / Supplier |
Specifications / Capacity / Range of application |
Accuracy of measurement |
Any other detail |
| |
Water and Wastewater Analysis |
| 1 |
Digital pH Meter |
Elico India |
pH range : 0.00 to 14.00 pH |
±0.01 |
Resolution- ±0.01 |
| 2 |
Weighing Balance |
K- Roy |
Single Pan
Min.weighing –0.001 g
Max. weighing – 200.000 g |
±0.001g |
|
| 3 |
Visible Spectrophotometer (Digital) Model No. CL-310 |
Chemiline |
wavelength range – 340 to 990 nm |
±2 nm
±0.005 Abs |
|
| 4 |
UV-Visible spectrophotometer |
Systronics |
wavelength range – 200 to 1000 nm |
±0.1 nm |
|
| 5 |
Digital Flame
Photometer Model
No. CL-410 |
Chemi Line |
Sodium : 2 To 100 PPM K – 1 to 100 ppm Li – 2 to 25 ppm Ca – 30 to 300 ppm |
±2% & ±1 digit |
|
| 6 |
Oven (Hot Air) |
Labline |
14” x 14” x 14” (250 °C max.) |
±1 deg C |
|
| 7 |
COD Digestor |
Labline |
FOR 15 Samples
at a time |
|
|
| 8 |
Muffle Furnace |
Labline |
1150 °C Max. with silica and porcelein crucibles Size : 10” x 5” x 5” |
±0.3 deg C |
|
| 9 |
Heating Mantle |
Labline |
Cap. : 500 ML |
|
|
| 10 |
B.O.D Incubator |
- |
- |
|
|
| 11 |
Composite testing kit |
Aquasol |
Silica – 5 to 80 ppm Iron – 0 to 10 ppm Sulphate – min. 10 ppm |
|
|
| 12 |
Kjeldhal Assembly |
- |
Cap : 500 ml |
|
|
| 13 |
Distillation unit |
- |
3 litre/hr |
|
|
| 14 |
Digital Direct TDS meter |
Digital Instruments Corporation |
TDS measurement : 0 To 200000 PPM |
±1 % |
|
| 15 |
D.O. Meter |
Chemi Line |
DO measurement : 0 To 20 PPM |
±1 % |
0.1 ppm |
| 16 |
Hot Water Bath |
Jay lab Instruments |
6 Holes |
|
|
| 17 |
Gas Chromatograph |
Netal India Model No. Omega-QCT |
---- |
|
|
| |
Stack Monitoring & AAQM |
| 18 |
Stack Monitoring Kit |
Yash Engineers, Baroda |
With stack
velocity measurement,
Dry Gas Meter
and vacuum
pump, Rotameter
- 10 LPM, 100 LPM |
|
Temp – 0 to 500 C |
| 19 |
Handy Sampler (HC sampling) Model No. AS-2 |
Technovation Analytical Inst. (P) Ltd., Mumbai |
Rotameter 0.5 PM |
|
|
| 20 |
High Volume Air Sampler (Carbon Brushless) |
Yash Engineers, Baroda |
Model – HNS/HVS/21 |
|
|
| 21 |
Respirable particulate matter sampler |
Yash Engineers, Baroda |
For PM10 measurement |
|
|
| 22 |
Respirable dust
sampler ( for
particulate matter
less than 2.5
micron) |
Yash Engineers, Baroda |
for the
monitoring of
Respirable dust
and gaseous
pollutants like
SO2, NOx etc.
With inbuilt
stabiliser, timer,
time totaliser
including gaseous
assembly for
gaseous measurement, With PM 10 and PM 2.5 impactor anufactured
as per design
standardize by USEPA and
brushless motor. |
|
|
| 23 |
Dragger Tubes and pump |
Uniphos Model No. – ASP-21 |
For Measuring
concentration of diff.solvents and chemical Range – 10 to 2000 ppm |
|
|
| |
Noise Monitoring |
| 24 |
Noise Level Meter |
Lutron Model : SL4010 |
Range : 30 to
130 dB
(3 ranges) |
Resolution – 0.1dB |
|
| 25 |
Weather monitoring station |
Yash Engineers, Baroda |
Consists of :
1. Anemometer - measures wind speed 200 km/hr and direction 359 Deg,
2. Self-emptying Rain Gauge- measures rainfall 0 to 999 mm/hr
3. Indoor temperature 50 Deg C,
4. Humidity 2 to 98% RH
5. Barometric Pressure 795 to 1050 mb
6. Outdoor temperature and humidity 60 Deg C, 98 % RH
7. Tripod stand, RS 232 cable and software |
|
|
| |
Microbiological Analysis |
| 26 |
Microscope |
C X L Plus |
2 x 2 x 2 Feet |
|
|
| |
Laminar Air
Flow |
Labline |
---- |
|
|
| |
Autoclave |
---- |
CL - 910 ,
Count 9999 |
|
|
| |
Digital Colony
Counter |
Chemi line |
Cap. : 2 litres |
|
|
| |
Magnetic Stirrer
With Hot Plate
|
Jay lab Instruments |
|
|
|
|
| |
|
 |
TESTING AND CERTIFICATION BY COMPETENT PERSON (CPS) |
| |
Periodic examination and testing by Competent Person, as per Factories Act 1948, including external
examination, internal examination, Hydraulic/Pneumatic test, Ultrasonic thickness measurement (NDT) |
| |
|
 |
lifting tools and tackles (section 29) |
 |
hoists & lifts (section 28) |
 |
pressure vessels (section 31) |
 |
dangerous machinery (Centrifuge, power press etc.-Section 21) |
| |
|
 |
CERTIFICATE OF STABILITY |
| |
We are also associated with recognized competent person for certificate of stability, which is required to
be obtained for every building/civil structure within the factory premises as per section 6 & 112 of Factories
Act.
Our competent person is also Govt. Registered Valuer for valuation of civil structures, buildings, etc. |
| |
|
 |
Infrastructure and support system for Competent Person services (CPS) |
 |
We have hydraulic pumps for carrying out hydraulic tests of pressure vessels. |
 |
We also have Ultrasonic Thickness measurement machine (MS, SS range 1-100 mm thickness) |
 |
We have necessary manpower required for carrying out the tests of lifting tools & tackles, pressure
vessels, hoists & lifts, etc. The tests are carried out with complete support towards plant operation,
with proper scheduling. Suggestions for improvement are also given by our competent persons
based on their expertise gained during their course of service. |
 |
We have authentic literature on Factories Act 1948, Gujarat Factories Act 1984 and continuously
upgrade our knowledge regarding amendments and notifications issued by Factories Inspectorate. |
| |
|
 |
SERVICES IN THE FIELD OF SAFETY |
| |
In today’s scenario, safety of plant and personnel is given due importance owing to statutory
compliance as well as the overall benefit gained in production activities. Hence, documentation
and implementation of safety are dealt with more professional approach. Technical skill along
with sound knowledge of safety is required for this purpose. In our team, we have qualified
safety professional who have experience and expertise in safety aspects of chemical industry and
are well conversant with the various statutory requirements of Factory Act, OSHA, etc. |
| |
|
 |
Our safety services include |
 |
Safety audit as per the guidelines of Indian standards, Factories Inspectorate |
 |
Preparation of On-site emergency plan as per the guidelines of Factory Act. |
 |
Preparation of safety manual, First Aid manual, etc. |
 |
Monthly Safety Inspection, Safety Training |
 |
HAZOP& HAZAN Study |
 |
Statutory work and documentation as per rule no. 41B, 68K, L, and P of Factory Act. |
| |
|
 |
Infrastructure and support system for Safety services : |
 |
We have authentic literature on Factories Act 1948, Gujarat Factories Act 1984, IS guidelines and
procedures for safety audits, onsite & offsite emergency plans, Hazop & Hazan studies etc. |
 |
We also make use of latest versions of softwares for HAZAN and HAZOP (such as HAZOP-Pro,
PHAST) as well as Risk Assessment studies (such as ALOHA and CAMEO) which are downloaded
as and when required. |
 |
We are in constant touch with industries and acknowledge ourselves with the latest developments,
new safety equipments introduced, and safety issues raised from time to time. We study the
incidents caused in industries and use the outcomings to improvise our safety documentation. |
| |
|
| |
|